All Tools

Infrastructure Engineering

Cable Distance Tool

Find maximum signal transport distances for HDMI, HDBaseT, fiber, CAT6, SDI, USB, and AV-over-IP infrastructure.

Filter by Signal Type

Results (17)

HDMI 2.0Passive HDMI

4K@60Hz 4:4:4

Use certified premium high-speed HDMI cable.

16ft

5 m

HDMI 2.0Active Optical HDMI

4K@60Hz 4:4:4

Fiber-based active HDMI. Directional — verify source/display ends.

328ft

100 m

HDMI 2.0Passive HDMI

4K@60Hz 4:2:0

4:2:0 chroma subsampling allows longer passive runs.

33ft

10 m

HDMI 2.1Ultra High Speed HDMI

8K@60Hz / 4K@120Hz

Limited passive distance. Use fiber for longer runs.

10ft

3 m

HDBaseTCAT6/6A

4K@60Hz 4:2:0

Requires shielded CAT6A for 4K. Supports PoC, IR, RS-232.

328ft

100 m

HDBaseT 3.0CAT6A

4K@60Hz 4:4:4

Uncompressed 4K 4:4:4 over CAT6A. Bi-directional USB support.

328ft

100 m

SDI (3G)RG6 Coax

1080p@60Hz

Standard broadcast infrastructure. Belden 1694A recommended.

328ft

100 m

SDI (12G)RG6 Coax

4K@60Hz

Use Belden 4694R or equivalent for 12G-SDI.

197ft

60 m

SDI (12G)Fiber (Single-mode)

4K@60Hz

SFP+ transceivers required. Excellent for long campus runs.

32,808ft

10,000 m

USB 3.0Passive USB 3.0

Data / 5Gbps

Use active extender or USB-over-IP for longer distances.

10ft

3 m

USB 2.0Passive USB 2.0

Data / 480Mbps

For basic peripherals. Use USB extenders over CAT for conference rooms.

16ft

5 m

USB 2.0USB over CAT5e

Data / 480Mbps

Active USB extender pair required.

164ft

50 m

AV-over-IP (1Gbps)CAT6/6A

4K@60Hz (compressed)

Visually lossless compression. Works on standard network switches.

328ft

100 m

AV-over-IP (10Gbps)CAT6A / Fiber

4K@60Hz 4:4:4

Uncompressed or light compression. Requires 10G network infrastructure.

328ft

100 m

Dante AudioCAT5e/6

Up to 512 channels

Standard Ethernet. Redundant network recommended.

328ft

100 m

Fiber (Multi-mode)OM3 / OM4

10Gbps

OM4 extends to 400m at 10Gbps. Use for in-building backbone runs.

984ft

300 m

Fiber (Single-mode)OS2

10Gbps+

Campus and inter-building connectivity. Future-proof infrastructure.

32,808ft

10,000 m

Engineering Notes

  • • All distances are maximum rated — actual performance depends on cable quality, termination, and environment.
  • • For structured cabling, always use plenum-rated cable in air handling spaces per NEC code.
  • • Fiber is recommended for any run exceeding 100m or between buildings.
  • • AV-over-IP solutions offer the most flexibility for large-scale installations.

Designed for a specific project? We can help you apply these calculations.

Discuss Your Project
RADIANT
400 S 4th St Ste 401-414, Minneapolis MN 55415
Mon–Fri, 9:00 AM – 5:00 PM CST
Home